UCSF
 

 

 

Chunsheng Wang,   Ph.D

Posdoctoral Scholar
Department of Radiology
University of California San Francisco (UCSF)
Tel: +1 (415) 514-4870
Email: cwang@radiology.ucsf.edu


Education:

2007.2 - Now      -- Postdoctoral Scholar, Dept. of Radiology, University of California San Francisco (UCSF),
                                USA
2002.9 - 2006.9   -- Ph.D, Dept. of Electrical and Electronic Engineering, The University of Hong Kong (HKU),
                                Hong Kong, China
1999.9 - 2002.7   -- M. S, Dept. of Comp Sci. & Tech., Univ. of Sci. & Tech. of China (USTC), AnHui, China
1994.9 - 1999.7   -- B. E, Dept. of Comp Sci. & Tech., Univ. of Sci. & Tech. of China, (USTC), AnHui, China
1994.9 -1999.7    -- B. S, Dept. of Chem., Univ. of Sci. & Tech. of China, (USTC), AnHui, China



Research Interests

  • RF coil design for MRI: Ultra high field volume coils and coil array
  • Electromagnetic calculation and analysis
  • Parallel imaging in MRI


Selected Publications

[1] Wang CS, Shen GX, "B1 Field, SAR and SNR Comparisons for Birdcage, TEM and Microstrip Coils at 7T"
  Journal of Magnetic Resonance Imaging, 24 (2006) 439-443
[2] Wang CS, Qu P, Shen GX, "Potential Advantage of High Modes of Birdcage for Parallel Imaging", Journal
of Magnetic Resonance,
182(2006) 160-167
[3] Wang CS, Shen GX, etc, "Theoretical and Experimental Investigation of Relationship among SAR, Tissue
and Radio Frequencies in MRI", Physica Medica, Vol. XXI(2) (2005) 61-64
[4] Qu P, Wang CS, Shen GX, "Adaptive regularization for GRAPPA reconstruction", Journal of Magnetic
Resonance Imaging
24(2006) 248-255
[5] Qu P, Shen GX, Wang CS, etc., "Tailored utilization of acquired k-space points for GRAPPA
reconstruction", Journal of Magnetic Resonance, 174(2005) 60-67
[6] Yuan J, Shen GX, Wang CS, etc. "Use of Bi-2223 multifilamentary tapes as RF coils for 1.5T MRI
application", Physica C, 415(2004) 189 -196.
[7] Wu B, Qu P, Wang CS, Yuan J, Shen GX. "Interconnecting L/C components for decoupling and its
application to the low- field open MRI array", Magnetic Resonance Engineering 31B (2007) 116-126
[8]Wang CS, Cheng YM, Wang YX, "In Self-adaptive Digital Watermarking Algorithm" Computer
Engineering and Applications (Chinese)
, 21(2002), 106-109
[9]Wang CS, Cheng YM, Wang YX, "Novel Digital Watermarking Algorithm Based on the Classification
of Image Blocks",Microcomputer and Applications (Chinese), 6(2002), 54-57

[10] Wang CS, Shen GX, "Relationship among SAR, RF frequency and Tissue" 11th ISMRM (2003), p2442,
Toronto, Canada.
[11] Wang CS, Yuan J, Shen GX, Wu B, "Comparison of B1 Field Homogeneity for Shield Birdcage, TEM and
Microstrip Volume Coils at 300MHz" 12th ISMRM (2004), p487, Kyoto, Japan
[12] Wang CS, Yuan J Shen GX, Qu P, "Theoretical and experimental investigation of the relationship among
SAR, Tissues and RF frequencies in MRI", 12th ISMRM (2004), p1668, Kyoto, Japan
[13]Wang CS, Qu P, Shen GX, "Potential Advantage of High Modes of Birdcage for Parallel Imaging",
Proc. 14th ISMRM (2006), p 2564, Seattle, USA.
[14]Wang CS, Shen GX, "Comparison of Three Applied Volume Coils at 7T", Proc. 14th ISMRM (2006),
p3533, Seattle, USA.
[15]Wang CS, Shen GX, "Optimization of a multi-channel transmit, Quadrature Receive Birdcage Coil",
Proc. 14th ISMRM (2006), p 3539, Seattle, USA.
[16]Wang CS, Qu P, Yuan J, Shen GX. "Evaluation of a Degenerated Birdcage Coil for Parallel Imaging" 15th
ISMRM(2007), Berlin, Germany
[17]Wang CS, Pang Y, Wu B, Shen GX. "SAR and B1 Field in a Human Model for Birdcage, TEM and
Microstrip Coils at 7T" 15th ISMRM(2007), Berlin, Germany
[18]Wang CS, Zhang X, "B1 Field Optimization for Microstrip Transmission Line Volume Coil at High Field", 16th
ISMRM (2008), p1182, Toronto, Canada
[19]Wang CS, Wu B, Xu D, Zhang X, "A Novel Double-tuned Head Coil with 16 Double-tuned emements for 7T
MRI/S", 16th ISMRM (2008), p2983, Toronto, Canada
[20] Wang C, Pai A, Wu B, Krug R, Majumda S, Zhang X, "A Microstrip Volume Coil with Easy Access for Wrist
Imaging at 7T", 17th ISMRM (2009), p2946, Hawaii, USA
[21] Wang C, Wu B, Zhang X, "A Practical multi-tuned Birdcage Resonator for MRI/MRS at 7T", 17th ISMRM
(2009), P2965, Hawaii, USA
[22] Wang C, Zhang X, "Evaluation of B1+ and E field of RF Resonator with High Dielectric Insert ", 17th ISMRM
(2009), p3054, Hawaii, USA

 


 


Biograd
University of California San Francisco 2008
This page was last updated on Mar. 19, 2008
 Contact Us
department of radiology UCSF medical center search UCSF about UCSF UCSF homepage